The high precision line of hand-held linear polarimeter is designed for applications demanding the highest accuracy. They are non imaging, linear polarimeter's designed to measure the first three components of the Stokes vector and report the degree of linear polarization (DoLP) and the polarization orientation. Each sensor is compact, light, easy to operate and comes with control as well as calibration software. They operate wirelessly and up to ten sensors may be networked and logged concurrently. Note that these sensors can be easily tailored to users specifications including wavelength, polarimetric completeness, input aperture, etc.

Applications
     - Phenomenology studies
     - Atmospheric Measurements
     - Quality Control

Benefits
     - High accuracy measurements
     - Easily positioned and aimed
     - Remote operation - wireless data collection/logging
     - Self contained
     - Pre calibrated
     - Portable

Specifications
     - Accuracy - +/- 0.25% DOLP, +/- 0.10° orientation
     - Precision - +/- 0.02% DOLP, +/- 0.005° orientation
     - Data Acquisition Rate - 8 kHz (32 samples/point/channel)
     - Data Digitization Depth - 12 bits/channel
     - Input Aperture - 28 mm
     - Wavelength - 710nm, +/- 40nm (other wavelengths/wavebands available)
     - Power - 115 VAC
     - Requirements - Wireless router and control computer
     - Size, Weight - 35"W x 10"L x 5"H, 3 1/4 lbs

Data Acquisition Program
     - Operates multiple sensors simultaneously
     - Continuous file log of sensor data including: raw data,
        Stokes parameters, DoLP, orientation, tip, tilt, and compass heading.
     - Data can be logged in ASCII or binary format
     - Targeting camera image logging for one or more sensors at
        user defined intervals.
     - 2D Poincare plot with history tracking for one or more sensors.
     - 4 real-time strip charts to monitor a variety of sensor information.

Calibration Program
     - Permits user polarimetric calibration
     - Measure 4 known linear polarization states
     - Program calculates polarimetric calibration and data reduction matrices
     - Calibration data can be logged in ASCII or binary format.
     - 4 real-time strips charts to monitor a variety of sensor information